tess-mono-01 — TESS single-transit search
Search TESS SPOC light curves and cutouts for isolated transits, then audit each against detrending, blending, pointing and prior-art alternatives.
- Steps
- 5
- Targets
- 0
- Collection
- tess-mono-01
Campaigns · 180
A campaign is a finite, reviewable search: a declared target pool, a fixed sequence of analysis steps, thresholds calibrated before use, and a search log that keeps rejected leads and null results.
Search TESS SPOC light curves and cutouts for isolated transits, then audit each against detrending, blending, pointing and prior-art alternatives.
Known-object test on TOI-1019.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3.5, 3.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 10%, 10%, 0%, 10%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 247 threshold entries outside the known-signal veto across 6 light curve(s), forming 45 distinct event(s), 36 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1059.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, 3, 4.5, 5.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 1%, 2%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 10%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 318 threshold entries outside the known-signal veto across 6 light curve(s), forming 128 distinct event(s), 23 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1114.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3, 3.5, 4.5, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 10%, 20%, 10%, 10%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 1032 threshold entries outside the known-signal veto across 6 light curve(s), forming 180 distinct event(s), 123 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1124.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5, ≤2.5, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 10%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 819 threshold entries outside the known-signal veto across 5 light curve(s), forming 299 distinct event(s), 58 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1149.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 110 threshold entries outside the known-signal veto across 4 light curve(s), forming 55 distinct event(s), 3 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1192.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5, ≤2.5, 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 45 threshold entries outside the known-signal veto across 6 light curve(s), forming 18 distinct event(s), 3 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-121.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, 5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 0.5%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 10%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 297 threshold entries outside the known-signal veto across 6 light curve(s), forming 91 distinct event(s), 30 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1229.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, 3.5, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 10%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 130 threshold entries outside the known-signal veto across 6 light curve(s), forming 22 distinct event(s), 14 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1351.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 4, 3.5, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 10%, 0%, 0%, 0%, 0%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 342 threshold entries outside the known-signal veto across 6 light curve(s), forming 60 distinct event(s), 38 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1356.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3.5, 3, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 245 threshold entries outside the known-signal veto across 6 light curve(s), forming 85 distinct event(s), 16 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1379.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 56 threshold entries outside the known-signal veto across 3 light curve(s), forming 11 distinct event(s), 8 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1433.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* —, 6, —, 5.5, 8, 4.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 71 threshold entries outside the known-signal veto across 6 light curve(s), forming 11 distinct event(s), 11 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1455.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, 3.5, 3, 4; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 324 threshold entries outside the known-signal veto across 6 light curve(s), forming 58 distinct event(s), 50 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1457.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 20%, 10%, 80%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 613 threshold entries outside the known-signal veto across 3 light curve(s), forming 205 distinct event(s), 38 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1461.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2% (completeness for 2000 ppm: 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 131 threshold entries outside the known-signal veto across 2 light curve(s), forming 35 distinct event(s), 16 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1528.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 4, 4.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 110 threshold entries outside the known-signal veto across 3 light curve(s), forming 18 distinct event(s), 13 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-162.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2% (completeness for 2000 ppm: 0%). The null result excludes only dips deeper than that. Residual screen: 33 threshold entries outside the known-signal veto across 1 light curve(s), forming 11 distinct event(s), 4 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1656.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 118 threshold entries outside the known-signal veto across 2 light curve(s), forming 60 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1709.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 79 threshold entries outside the known-signal veto across 2 light curve(s), forming 25 distinct event(s), 8 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-173.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3.5, 3.5, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 340 threshold entries outside the known-signal veto across 6 light curve(s), forming 89 distinct event(s), 30 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1861.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, ≤2.5, 3, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 0.5%, 0.5%, 1%, 0.5% (completeness for 2000 ppm: 10%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 93 threshold entries outside the known-signal veto across 6 light curve(s), forming 35 distinct event(s), 5 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1949.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: TOI-1949.01: no SPOC 120-s light curve found at MAST for TIC 334125713. no products to analyse: none pinned and none found for the requested targets (TOI-1949.01: no SPOC 120-s light curve found at MAST for TIC 334125713.)
Known-object test on TOI-1976.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 10%, 20%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 674 threshold entries outside the known-signal veto across 4 light curve(s), forming 229 distinct event(s), 48 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1986.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 4, ≤2.5, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 194 threshold entries outside the known-signal veto across 6 light curve(s), forming 60 distinct event(s), 28 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2031.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, 3, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 10%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 205 threshold entries outside the known-signal veto across 6 light curve(s), forming 43 distinct event(s), 29 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2108.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, ≤2.5, 4; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, none on grid, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 264 threshold entries outside the known-signal veto across 4 light curve(s), forming 63 distinct event(s), 24 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2137.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, 2%, 2% (completeness for 2000 ppm: 0%, 10%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 132 threshold entries outside the known-signal veto across 5 light curve(s), forming 30 distinct event(s), 19 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2183.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: TOI-2183.01: no SPOC 120-s light curve found at MAST for TIC 1715469662. no products to analyse: none pinned and none found for the requested targets (TOI-2183.01: no SPOC 120-s light curve found at MAST for TIC 1715469662.)
Unverified lead: four 74–78 ppt events are compatible with a 31.5798-d timing family; host RUWE 9.18 and E4 pointing/localization failures prevent a physical classification. See current dossier and 2026-09-27 archive verification.
Known-object test on TOI-2349.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2% (completeness for 2000 ppm: 0%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 153 threshold entries outside the known-signal veto across 3 light curve(s), forming 20 distinct event(s), 19 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2613.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 10%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 374 threshold entries outside the known-signal veto across 4 light curve(s), forming 52 distinct event(s), 46 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2645.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, ≤2.5, 3, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 20%, 0%, 30%, 0%, 0%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 674 threshold entries outside the known-signal veto across 6 light curve(s), forming 115 distinct event(s), 111 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2782.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 4, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid (completeness for 2000 ppm: 10%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 642 threshold entries outside the known-signal veto across 2 light curve(s), forming 112 distinct event(s), 105 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3012.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 423 threshold entries outside the known-signal veto across 4 light curve(s), forming 90 distinct event(s), 69 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3048.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 10%, 0%). The null result excludes only dips deeper than that. Residual screen: 811 threshold entries outside the known-signal veto across 4 light curve(s), forming 152 distinct event(s), 54 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3098.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 10%, 30%, 0%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 281 threshold entries outside the known-signal veto across 5 light curve(s), forming 50 distinct event(s), 34 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3157.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, ≤2.5, 3, 3.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 330 threshold entries outside the known-signal veto across 6 light curve(s), forming 83 distinct event(s), 45 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-316.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5, 4; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 73 threshold entries outside the known-signal veto across 4 light curve(s), forming 14 distinct event(s), 9 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3223.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3.5, 4; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 851 threshold entries outside the known-signal veto across 3 light curve(s), forming 189 distinct event(s), 110 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3241.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, ≤2.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, none on grid, none on grid (completeness for 2000 ppm: 0%, 10%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 790 threshold entries outside the known-signal veto across 6 light curve(s), forming 297 distinct event(s), 36 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3312.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 10%, 0%). The null result excludes only dips deeper than that. Residual screen: 658 threshold entries outside the known-signal veto across 3 light curve(s), forming 144 distinct event(s), 66 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-340.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 4, 3.5, 7, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 433 threshold entries outside the known-signal veto across 6 light curve(s), forming 164 distinct event(s), 32 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3460.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 20%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 913 threshold entries outside the known-signal veto across 4 light curve(s), forming 308 distinct event(s), 24 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3487.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 10%). The null result excludes only dips deeper than that. Residual screen: 404 threshold entries outside the known-signal veto across 6 light curve(s), forming 149 distinct event(s), 29 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3491.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 50%, 30%, 10%, 10%). The null result excludes only dips deeper than that. Residual screen: 786 threshold entries outside the known-signal veto across 5 light curve(s), forming 205 distinct event(s), 73 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3501.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 125 threshold entries outside the known-signal veto across 4 light curve(s), forming 44 distinct event(s), 7 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-352.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 59 threshold entries outside the known-signal veto across 3 light curve(s), forming 17 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3531.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5, 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 10%, 10%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 280 threshold entries outside the known-signal veto across 6 light curve(s), forming 53 distinct event(s), 38 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3586.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, ≤2.5, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 216 threshold entries outside the known-signal veto across 6 light curve(s), forming 48 distinct event(s), 24 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3716.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 517 threshold entries outside the known-signal veto across 2 light curve(s), forming 99 distinct event(s), 36 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3972.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 2%, 1% (completeness for 2000 ppm: 0%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 48 threshold entries outside the known-signal veto across 3 light curve(s), forming 12 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4381.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, 8, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 530 threshold entries outside the known-signal veto across 5 light curve(s), forming 92 distinct event(s), 40 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4398.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 679 threshold entries outside the known-signal veto across 4 light curve(s), forming 160 distinct event(s), 22 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4422.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 10%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 1268 threshold entries outside the known-signal veto across 4 light curve(s), forming 293 distinct event(s), 100 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4427.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 10%, 0%, 0%, 0%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 164 threshold entries outside the known-signal veto across 5 light curve(s), forming 37 distinct event(s), 22 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-447.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 30%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 309 threshold entries outside the known-signal veto across 4 light curve(s), forming 115 distinct event(s), 35 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4494.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.2%, 0.2% (completeness for 2000 ppm: 90%, 100%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 208 threshold entries outside the known-signal veto across 2 light curve(s), forming 79 distinct event(s), 13 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-450.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, —, 5, 7, —; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 147 threshold entries outside the known-signal veto across 5 light curve(s), forming 38 distinct event(s), 17 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4543.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5% (completeness for 2000 ppm: 30%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 133 threshold entries outside the known-signal veto across 2 light curve(s), forming 50 distinct event(s), 9 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4597.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 19 threshold entries outside the known-signal veto across 2 light curve(s), forming 4 distinct event(s), 3 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5149.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5, 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 10%, 10%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 122 threshold entries outside the known-signal veto across 6 light curve(s), forming 33 distinct event(s), 12 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-527.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3, 3, 3, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.2%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 10%, 40%, 100%, 30%, 10%, 40%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 156 threshold entries outside the known-signal veto across 6 light curve(s), forming 57 distinct event(s), 10 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5379.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 81 threshold entries outside the known-signal veto across 2 light curve(s), forming 29 distinct event(s), 5 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5394.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3.5, 3.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 1%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 96 threshold entries outside the known-signal veto across 4 light curve(s), forming 35 distinct event(s), 8 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5575.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 72 threshold entries outside the known-signal veto across 5 light curve(s), forming 16 distinct event(s), 11 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5670.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: TOI-5670.01: no SPOC 120-s light curve found at MAST for TIC 860207014. no products to analyse: none pinned and none found for the requested targets (TOI-5670.01: no SPOC 120-s light curve found at MAST for TIC 860207014.)
Known-object test on TOI-573.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 4.5, 4, 3.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 10%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 83 threshold entries outside the known-signal veto across 4 light curve(s), forming 28 distinct event(s), 7 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-585.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 20%, 0%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 117 threshold entries outside the known-signal veto across 3 light curve(s), forming 37 distinct event(s), 12 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5861.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid (completeness for 2000 ppm: 0%). The null result excludes only dips deeper than that. Residual screen: 70 threshold entries outside the known-signal veto across 1 light curve(s), forming 13 distinct event(s), 7 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-588.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, ≤2.5, 6, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.2%, 0.2%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 100%, 100%, 60%, 60%, 80%, 80%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 675 threshold entries outside the known-signal veto across 6 light curve(s), forming 314 distinct event(s), 7 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6022.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, —, ≤2.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 10%, 0%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 609 threshold entries outside the known-signal veto across 5 light curve(s), forming 108 distinct event(s), 93 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6036.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1% (completeness for 2000 ppm: 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 147 threshold entries outside the known-signal veto across 1 light curve(s), forming 26 distinct event(s), 23 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6106.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 195 threshold entries outside the known-signal veto across 2 light curve(s), forming 24 distinct event(s), 22 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6137.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: TOI-6137.01: no SPOC 120-s light curve found at MAST for TIC 44295981. no products to analyse: none pinned and none found for the requested targets (TOI-6137.01: no SPOC 120-s light curve found at MAST for TIC 44295981.)
Known-object test on TOI-621.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5% (completeness for 2000 ppm: 0%, 30%). The null result excludes only dips deeper than that. Residual screen: 141 threshold entries outside the known-signal veto across 2 light curve(s), forming 28 distinct event(s), 16 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-630.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 4, 4; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 10%, 20%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 218 threshold entries outside the known-signal veto across 3 light curve(s), forming 38 distinct event(s), 33 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6564.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 1% (completeness for 2000 ppm: 20%, 10%, 10%, 20%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 389 threshold entries outside the known-signal veto across 5 light curve(s), forming 137 distinct event(s), 34 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6568.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 400 threshold entries outside the known-signal veto across 5 light curve(s), forming 149 distinct event(s), 7 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6650.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 6, 3.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 134 threshold entries outside the known-signal veto across 4 light curve(s), forming 37 distinct event(s), 13 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-668.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, 3.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 10%, 10%, 10%, 10%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 735 threshold entries outside the known-signal veto across 5 light curve(s), forming 179 distinct event(s), 37 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-671.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 387 threshold entries outside the known-signal veto across 5 light curve(s), forming 166 distinct event(s), 24 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6798.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 10%, 0%, 0%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 907 threshold entries outside the known-signal veto across 6 light curve(s), forming 185 distinct event(s), 73 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6806.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3.5, ≤2.5, 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 1%, 1%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 10%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 229 threshold entries outside the known-signal veto across 6 light curve(s), forming 69 distinct event(s), 19 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6815.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid (completeness for 2000 ppm: 0%, 10%). The null result excludes only dips deeper than that. Residual screen: 58 threshold entries outside the known-signal veto across 2 light curve(s), forming 17 distinct event(s), 9 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-7018.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: TOI-7018.01: no SPOC 120-s light curve found at MAST for TIC 156512187. no products to analyse: none pinned and none found for the requested targets (TOI-7018.01: no SPOC 120-s light curve found at MAST for TIC 156512187.)
Known-object test on TOI-706.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3.5, ≤2.5, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 10%, 10%, 10%, 10%, 40%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 224 threshold entries outside the known-signal veto across 6 light curve(s), forming 99 distinct event(s), 8 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-7388.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 10%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 1283 threshold entries outside the known-signal veto across 3 light curve(s), forming 236 distinct event(s), 201 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-7420.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: TOI-7420.01: no SPOC 120-s light curve found at MAST for TIC 259188347. no products to analyse: none pinned and none found for the requested targets (TOI-7420.01: no SPOC 120-s light curve found at MAST for TIC 259188347.)
Known-object test on TOI-7464.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 30 threshold entries outside the known-signal veto across 2 light curve(s), forming 5 distinct event(s), 5 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-760.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 10%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 209 threshold entries outside the known-signal veto across 6 light curve(s), forming 65 distinct event(s), 14 persistent in SAP and PDCSAP at two or more baselines.
Pipeline check after follow-up: the 15.8 ppt S99 event repeatedly fails target localization, and the exact host has a Gaia DR3 SB1 orbit with P 90.4224 d, K1 12.14 km/s and a stellar-mass companion. The photometric anomaly is preserved, but the exoplanet lead is retired; see REJECTION.md.
Known-object test on TOI-764.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 1%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 20%, 10%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 321 threshold entries outside the known-signal veto across 6 light curve(s), forming 60 distinct event(s), 36 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-768.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2% (completeness for 2000 ppm: 10%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 96 threshold entries outside the known-signal veto across 3 light curve(s), forming 16 distinct event(s), 11 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-7714.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 2% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 82 threshold entries outside the known-signal veto across 3 light curve(s), forming 33 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-7780.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: TOI-7780.01: no SPOC 120-s light curve found at MAST for TIC 437346961. no products to analyse: none pinned and none found for the requested targets (TOI-7780.01: no SPOC 120-s light curve found at MAST for TIC 437346961.)
Known-object test on TOI-7814.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: TOI-7814.01: no SPOC 120-s light curve found at MAST for TIC 279356. no products to analyse: none pinned and none found for the requested targets (TOI-7814.01: no SPOC 120-s light curve found at MAST for TIC 279356.)
Known-object test on TOI-830.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 2%, 1%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 264 threshold entries outside the known-signal veto across 6 light curve(s), forming 110 distinct event(s), 15 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-850.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2% (completeness for 2000 ppm: 0%). The null result excludes only dips deeper than that. Residual screen: 0 threshold entries outside the known-signal veto across 1 light curve(s).
Known-object test on TOI-890.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid (completeness for 2000 ppm: 0%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 79 threshold entries outside the known-signal veto across 2 light curve(s), forming 14 distinct event(s), 13 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-911.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 1%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 10%, 0%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit gap (1 covered epoch). Residual screen: 1221 threshold entries outside the known-signal veto across 4 light curve(s), forming 493 distinct event(s), 23 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-125.04: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3, ≤2.5, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 104 threshold entries outside the known-signal veto across 6 light curve(s), forming 53 distinct event(s), 3 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1301.02: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 79 threshold entries outside the known-signal veto across 6 light curve(s), forming 57 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1772.02: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 270 threshold entries outside the known-signal veto across 2 light curve(s), forming 127 distinct event(s), 4 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1812.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, ≤2.5, ≤2.5, 3, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 21 threshold entries outside the known-signal veto across 6 light curve(s), forming 9 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1835.02: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5% (completeness for 2000 ppm: 20%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 589 threshold entries outside the known-signal veto across 2 light curve(s), forming 230 distinct event(s), 21 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1893.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3, 3.5, 3, ≤2.5, 8; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 229 threshold entries outside the known-signal veto across 6 light curve(s), forming 86 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-1896.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 242 threshold entries outside the known-signal veto across 4 light curve(s), forming 108 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2003.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5% (completeness for 2000 ppm: 0%). The null result excludes only dips deeper than that. Residual screen: 1 threshold entry outside the known-signal veto across 1 light curve(s), forming 1 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2007.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3.5, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 53 threshold entries outside the known-signal veto across 6 light curve(s), forming 23 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2065.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 111 threshold entries outside the known-signal veto across 2 light curve(s), forming 41 distinct event(s), 5 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2085.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 116 threshold entries outside the known-signal veto across 6 light curve(s), forming 58 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2087.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 0.5%, 1%, 1%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 160 threshold entries outside the known-signal veto across 6 light curve(s), forming 64 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2098.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, ≤2.5, 3, 4, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 20%, 0%, 0%, 0%, 20%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 225 threshold entries outside the known-signal veto across 6 light curve(s), forming 98 distinct event(s), 4 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2102.02: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 2%, 2%, 2%, 2%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 117 threshold entries outside the known-signal veto across 6 light curve(s), forming 41 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-225.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 91 threshold entries outside the known-signal veto across 4 light curve(s), forming 38 distinct event(s), 5 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2263.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 94 threshold entries outside the known-signal veto across 6 light curve(s), forming 38 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2270.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 4.5, 3, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 40%, 50%, 30%, 70%, 40%, 50%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 366 threshold entries outside the known-signal veto across 6 light curve(s), forming 154 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2277.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5, 3.5, ≤2.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 50%, 20%, 10%, 10%, 40%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 505 threshold entries outside the known-signal veto across 6 light curve(s), forming 194 distinct event(s), 5 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2298.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3, ≤2.5, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 17 threshold entries outside the known-signal veto across 6 light curve(s), forming 11 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2300.03: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3.5, 4, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 74 threshold entries outside the known-signal veto across 6 light curve(s), forming 25 distinct event(s), 7 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2318.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 4, 3, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 213 threshold entries outside the known-signal veto across 6 light curve(s), forming 89 distinct event(s), 5 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2423.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 4.5, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 190 threshold entries outside the known-signal veto across 5 light curve(s), forming 69 distinct event(s), 8 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2433.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5, 3, 3, 4.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, none on grid, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 50 threshold entries outside the known-signal veto across 6 light curve(s), forming 22 distinct event(s), 4 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2435.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, 3, 3.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 2%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 46 threshold entries outside the known-signal veto across 6 light curve(s), forming 23 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2436.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, ≤2.5, 3.5, 3, 4.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 100 threshold entries outside the known-signal veto across 6 light curve(s), forming 41 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2456.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 272 threshold entries outside the known-signal veto across 2 light curve(s), forming 153 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2472.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 4; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 63 threshold entries outside the known-signal veto across 2 light curve(s), forming 24 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2490.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 20 threshold entries outside the known-signal veto across 3 light curve(s), forming 9 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2493.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 23 threshold entries outside the known-signal veto across 3 light curve(s), forming 13 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2530.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 46 threshold entries outside the known-signal veto across 4 light curve(s), forming 17 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2534.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3, 3, ≤2.5, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 216 threshold entries outside the known-signal veto across 6 light curve(s), forming 71 distinct event(s), 28 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2634.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 82 threshold entries outside the known-signal veto across 3 light curve(s), forming 37 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-2666.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 10, 3.5, 5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 20%, 30%, 30%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 59 threshold entries outside the known-signal veto across 3 light curve(s), forming 32 distinct event(s), 3 persistent in SAP and PDCSAP at two or more baselines. Repeat candidate: a persistent event matching the catalogued depth at BJD 2461049.1644 (ΔT 1790.01 d); 52 period aliases remain. Unverified lead until vetted.
Gaia DR3 cone, SIMBAD cone and Gaia DR3 NSS two-body cross-match of the TOI-2666.01 host, as a discriminating test for the TOI-2666.01 sector-99 repeat-event lead (V-shaped events; ExoFOP note "v-shaped; possible EB"; campaigns/tess-mono-01/LEAD_VETTING_LOG.md). Runner: No light-curve product was retrieved; only image/table/text products are available to screen.
Known-object test on TOI-285.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 4, 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 35 threshold entries outside the known-signal veto across 6 light curve(s), forming 17 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-289.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5, 3, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 75 threshold entries outside the known-signal veto across 6 light curve(s), forming 28 distinct event(s), 11 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-3500.02: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 185 threshold entries outside the known-signal veto across 4 light curve(s), forming 44 distinct event(s), 21 persistent in SAP and PDCSAP at two or more baselines. Repeat candidate: a persistent event matching the catalogued depth at BJD 2460757.1825 (ΔT 700.53 d); 8 period aliases remain. Unverified lead until vetted.
Known-object test on TOI-3724.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Residual screen: 146 threshold entries outside the known-signal veto across 3 light curve(s), forming 42 distinct event(s), 17 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4187.02: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 4, 3, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 50%, 20%, 10%, 10%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 185 threshold entries outside the known-signal veto across 5 light curve(s), forming 82 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-429.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 0.5%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 49 threshold entries outside the known-signal veto across 6 light curve(s), forming 22 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4309.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, ≤2.5, 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 138 threshold entries outside the known-signal veto across 5 light curve(s), forming 78 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4319.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, ≤2.5, ≤2.5, 4; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, 2%, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 339 threshold entries outside the known-signal veto across 5 light curve(s), forming 154 distinct event(s), 20 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4321.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3.5, ≤2.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.2%, 0.2%, 0.2%, 0.2%, 0.2%, 0.2% (completeness for 2000 ppm: 100%, 100%, 100%, 100%, 100%, 100%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 904 threshold entries outside the known-signal veto across 6 light curve(s), forming 406 distinct event(s), 20 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4355.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.2%, 0.2%, 0.2%, 0.2%, 0.2%, 0.5% (completeness for 2000 ppm: 100%, 100%, 100%, 100%, 90%, 80%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 366 threshold entries outside the known-signal veto across 6 light curve(s), forming 185 distinct event(s), 3 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4509.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, ≤2.5, 3.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 156 threshold entries outside the known-signal veto across 6 light curve(s), forming 72 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-4585.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5, ≤2.5, 3, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 124 threshold entries outside the known-signal veto across 6 light curve(s), forming 52 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5523.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, 3, 4, 10, 4; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 3 threshold entries outside the known-signal veto across 5 light curve(s), forming 2 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5563.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 4, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 11 threshold entries outside the known-signal veto across 4 light curve(s), forming 10 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5696.03: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 14 threshold entries outside the known-signal veto across 3 light curve(s), forming 5 distinct event(s), 3 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5719.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 1% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 34 threshold entries outside the known-signal veto across 2 light curve(s), forming 20 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5745.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 71 threshold entries outside the known-signal veto across 2 light curve(s), forming 34 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5812.02: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1% (completeness for 2000 ppm: 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 61 threshold entries outside the known-signal veto across 1 light curve(s), forming 11 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5870.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1% (completeness for 2000 ppm: 0%). The null result excludes only dips deeper than that. Residual screen: 6 threshold entries outside the known-signal veto across 1 light curve(s), forming 2 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-5893.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2% (completeness for 2000 ppm: 0%). The null result excludes only dips deeper than that. Residual screen: 20 threshold entries outside the known-signal veto across 1 light curve(s), forming 10 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6085.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 188 threshold entries outside the known-signal veto across 6 light curve(s), forming 74 distinct event(s), 3 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6650.04: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 6, 3.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1% (completeness for 2000 ppm: 10%, 10%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 142 threshold entries outside the known-signal veto across 4 light curve(s), forming 39 distinct event(s), 14 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6653.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5% (completeness for 2000 ppm: 0%). The null result excludes only dips deeper than that. Residual screen: 106 threshold entries outside the known-signal veto across 1 light curve(s), forming 52 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6663.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 2% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 4 threshold entries outside the known-signal veto across 2 light curve(s), forming 2 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6664.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3.5, 3, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 60%, 10%, 10%, 0%, 80%, 30%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 260 threshold entries outside the known-signal veto across 6 light curve(s), forming 134 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6666.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 3, ≤2.5, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 405 threshold entries outside the known-signal veto across 6 light curve(s), forming 147 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Gaia DR3 cone, SIMBAD cone and Gaia DR3 NSS two-body cross-match of the TOI-6666.01 host, as a discriminating test for the TOI-6666.01 repeat-event lead (one ~5.3 h feature at the start of sector 18, ΔT 171.5 d from the catalogued transit). An earlier ad-hoc SB2 attribution (P 4.8124683 d, e 0.053, K1 85.77 km/s, f(M) 0.31 Msun) was traced to Gaia source 4513527912472807936, 57.276 deg away, and is withdrawn; this campaign depends on it in no way. Runner: No light-curve product was retrieved; only image/table/text products are available to screen.
Known-object test on TOI-6667.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, 3, 3.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2%, 2%, 2%, 2%, 2% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 93 threshold entries outside the known-signal veto across 6 light curve(s), forming 31 distinct event(s), 11 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6670.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 239 threshold entries outside the known-signal veto across 6 light curve(s), forming 125 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6671.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 161 threshold entries outside the known-signal veto across 3 light curve(s), forming 91 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6672.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 66 threshold entries outside the known-signal veto across 4 light curve(s), forming 31 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6674.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth none on grid, none on grid, none on grid, none on grid (completeness for 2000 ppm: 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 75 threshold entries outside the known-signal veto across 4 light curve(s), forming 26 distinct event(s), 9 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6675.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, 3.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 64 threshold entries outside the known-signal veto across 6 light curve(s), forming 30 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6691.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3, ≤2.5, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit partial (1 covered epoch). Residual screen: 207 threshold entries outside the known-signal veto across 6 light curve(s), forming 92 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6692.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5, ≤2.5, ≤2.5, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1%, 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 106 threshold entries outside the known-signal veto across 6 light curve(s), forming 44 distinct event(s), 6 persistent in SAP and PDCSAP at two or more baselines.
Known-object recovery: S34 and S61 are published TOI-6695 b transits; prior candidate interpretation retracted 2026-09-27. S88 E2 rejected as off-target/pointing. See campaigns/toi-6695-01/REJECTION.md.
Known-object test on TOI-6698.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, ≤2.5, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 54 threshold entries outside the known-signal veto across 3 light curve(s), forming 28 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6890.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, 5.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1%, 1% (completeness for 2000 ppm: 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 165 threshold entries outside the known-signal veto across 3 light curve(s), forming 89 distinct event(s), 1 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6893.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 50%, 10%, 20%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 166 threshold entries outside the known-signal veto across 3 light curve(s), forming 78 distinct event(s), 4 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-6980.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3, 3, ≤2.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 20%, 10%, 40%, 70%). The null result excludes only dips deeper than that. Positive control: catalogued transit not recovered (1 covered epoch). Residual screen: 211 threshold entries outside the known-signal veto across 4 light curve(s), forming 90 distinct event(s), 0 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-7399.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* ≤2.5, ≤2.5, 3.5, 3, 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 287 threshold entries outside the known-signal veto across 6 light curve(s), forming 119 distinct event(s), 4 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-7857.01: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 2%, 2% (completeness for 2000 ppm: 10%, 10%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 48 threshold entries outside the known-signal veto across 2 light curve(s), forming 9 distinct event(s), 8 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-790.03: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 4, 3, 3, ≤2.5, 3; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 0.5%, 0.5%, 0.5%, 0.5%, 0.5%, 0.5% (completeness for 2000 ppm: 0%, 0%, 0%, 0%, 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 219 threshold entries outside the known-signal veto across 6 light curve(s), forming 83 distinct event(s), 19 persistent in SAP and PDCSAP at two or more baselines.
Known-object test on TOI-941.02: positive control on the catalogued transit(s), calibrated screen for further dips, catalogue cross-match. Runner: Calibration on each light curve (sign-flip null, injection–recovery): k* 3, 3.5; at the declared k = 5 the screen recovers ≥90% of 4-h dips only from depth 1%, 1% (completeness for 2000 ppm: 0%, 0%). The null result excludes only dips deeper than that. Positive control: catalogued transit recovered (1 covered epoch). Residual screen: 30 threshold entries outside the known-signal veto across 2 light curve(s), forming 10 distinct event(s), 2 persistent in SAP and PDCSAP at two or more baselines.
Declared test: isolated negative excursions ≥5 robust-MAD, ≥2 cadences, in both SAP and PDCSAP, outside ±0.08 phase of the known transit.